RAILWAYS

24V SMPS SPECIFICATION

INPUT VOLTAGE RANGE

  • Unregulated DC input with ripple content less than 4 V and varying between 85 to 250 V DC.

NOMINAL OUTPUT DC VOLTAGE :-

  • Two outputs of +24 V,1A.
  • Each output groups to be mutually isolated by 250 V DC.

PROTECTIONS:-

  • Power Supply shall not be damaged for input up to 250 V DC.
  • Shall work even with polarity reversed.
  • Output Protected for sudden load removal.
24V SMPS SPECIFICATION

CONTROL CARD FOR

CONTROL CARD FOR

  • Traction rectifier.
  • Traction Battery Charger.
  • Traction High Frequency Inverter.